PHABRIX Ships World’s First Portable 3G Eye & Jitter Test And Measurement Instrument

PHABRIX Ships World’s First Portable 3G Eye & Jitter Test And Measurement Instrument At IBC 2009

July 28, 2009

Newbury, Berkshire, United Kingdom – PHABRIX Ltd., a leading UK based test and measurement provider for video systems, announced the release of the PHABRIX SxE, the world’s only hand held portable eye and jitter test device operating at 3G-SDI, HD-SDI and SD-SDI to be shown at IBC Amsterdam.

With IBC just weeks away, PHABRIX, a leading provider of test and measurement instruments, will be shipping its revolutionary PHABRIX SxE in Hall 8 E23 at IBC. Offering 3G-SDI, HD-SDI, and SD-SDI analysis with eye and jitter measurement on a handheld platform, this world’s first is sure to be one of the big hits of the show.

This remarkable new unit has all the features of PHABRIX’s 2008 IABM award winning PHABRIX SxA with a combined generator, analyser and monitor enabling the user to generate at one standard and analyse at another. With AES support and 16 channels of audio, the PHABRIX SxE has already been pre-ordered by many existing companies delighted by the PHABRIX SxA. The PHABRIX SxE offers automatic measurements, multiple eyes, dedicated jitter screen, histograms and decade filters – features more associated with expensive bench bound products.

OB companies particularly will see the PHABRIX SxE as a much needed tool with eye measurements and error detection on cables as well as cable length parameters.

It is not often that a product is released that encapsulates so distinctly the essence of British ingenuity however the new SxE hand held test and measurement instrument with eye and jitter functionality from PHABRIX may just have set itself in that mould.

Having successfully launched the PHABRIX SxA, a three in one portable testing device at IBC2008, offering a combined generator, analyzer and monitor supporting three generations of SDI signals (3G-SDI, HD-SDI and SD-SDI), this UK based company demonstrated its 3G eye and jitter advancement on its stand at BVE2009 in February and now plans to launch the PHABRIX SxE officially at NAB2009 in April.

Phillip Adams, PHABRIX’s owner and Managing Director commented, “Eye and jitter measurement at 3Gbps is seen by many as the ‘Holy Grail’ of SDI interface testing, and the challenges of designing such functionality into a product, let alone a hand held one, are considerable. From the outset we set ourselves the task of creating a product which would not only address the needs of the industry to be compliant with SMPTE specifications but which would also offer the analysis tools required to determine the possible sources of non-compliance.

“One of the most significant challenges was the need to ensure low power consumption and to achieve this we had to go back to fundamental design principles. Space too was a factor and of course keeping the cost down was also essential. In the whole design we have tried to leverage mobile technologies – the processor, battery and power management circuits. Like all good innovators we have incorporated leading edge technology from other industries.

“In pure engineering terms the challenge required an eye sampling system with an analogue input bandwidth in excess of 7.5 GHz. The fundamental frequency of a 3Gbps signal is 1.5 GHz and to accurately represent that signal you need at least a third harmonic and preferably a fifth. Imagine the cost of an oscilloscope with this kind of input bandwidth and you can begin to understand the challenge.

“Another major challenge was to create a sampling clock with extremely low jitter, the creation of which is also pushing technological boundaries. At 3Gbps we have just 337 picoseconds across the eye which must be sampled with a clock with significantly better than 33 picoseconds peak to peak jitter.”

The PHABRIX SxE is available in a standard form with tools focussed on confirming compliance to SMPTE specifications. A single screen displays an eye diagram and jitter thermometers providing the engineer with a quick go/no-go indication and is intended as a fast, portable device for engineers. Applications include OB trucks, transmission stations through to large broadcast installations.

The analysis option for the PHABRIX SxE adds an additional jitter screen plus enhancements to the eye display and is focussed toward broadcast manufacturers who have a need for high end analysis tools at an affordable price. Here the PHABRIX SxE uses hardware and software algorithms usually associated with very expensive bench-bound equipment.

Histograms give statistical information which can be used to accurately measure rise time, fall time and amplitude. These automatic accurate measurements can then be logged for extended periods of time. Measurements like rise time and fall time are notoriously difficult to make with SDI signals and here the PHABRIX SxE excels, providing user friendly automatic measurements even in the presence of excessive jitter.

In addition to the standard timing and alignment jitter filters, decade filters are provided allowing an engineer to analyse the frequency content of any jitter present. The number of eyes displayed is adjustable from one eye up to one frame of eyes – a very useful feature for detecting source related power supply problems.

Multiple eye selection also enables analysis when serialiser jitter is present: Products process video in either a 10 or 20 bit parallel data domain which is subsequently transmitted as a single bit serial data stream. By triggering every 10 or 20 eyes you can reveal repetitive parallel clock domain jitter in equipment being analysed.

The separate jitter analysis screen incorporated into the advanced option enables the engineer to analyse the nature of jitter present using a graph of jitter versus time. Again, the decade filters are present and the time base can be adjusted from 1 line through to 1 frame. By analysing jitter in this detailed way an engineer can determine if a signal is in or out of specification and also get a feel for where any problems lie. A spiky waveform could indicate power supply noise and these visual clues aid the diagnosis. Vertical gain and horizontal magnify controls are provided to help further identify problems.

With all the generation, analysis and monitoring tools of the highly successful SxA, the PHABRIX SxE with eye and jitter is set to create quite an entrance at NAB2009. Held within a newly designed extruded aluminium case with its distinctive PHABRIX brand end caps, the PHABRIX SxE will be on every broadcast engineer’s wish list – and the price is comparable to a single option on many of its high end competitors’ products.

In a new announcement, PHABRIX will also be releasing it’s PHABRIX SxD, a dual link version of the range targeted at high end post facilities and studios offering 3G Level A and Level B support. Philip Adams, PHABRIX’s founder and managing director said: ‘The PHABRIX SxE is a key technological advance for the broadcast industry and for PHABRIX. We’ve a lot to shout about on our stand this year with the PHABRIX SxE, PHABRIX SxA and PHABRIX SxD all available.’ (Source: PHABRIX Ltd.)

The following two tabs change content below.
Mike is a finance industry executive with expertise in test, IT and avionics equipment acquisition, resale, residual valuation, leasing, renting and consignment.
This entry was posted in Manufacturer News, Product News, Test & Measurement and tagged , , , , , , . Bookmark the permalink.

Leave a Reply

Your email address will not be published. Required fields are marked *


two × 3 =

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>